Planning of the main distribution network in Cihampelas District, West Bandung Regency has a total water requirement 544.02 liters/second with a water leakage rate of 39.6 percent. This planning uses a gravity flow system with a branch pipe network pattern following the main district road. Hydraulic analysis to use EPANET 2.0 software with 3 aspects reviewed, namely pressure, velocity, and unit headloss